The VFD allows you to control the airflow thru your sys. by changing the fan speed.It also allows you to dial the system to the most efficient operating point.
https://www.dustcollectorhq.com/wp-content/uploads/vfd-2.jpg7201280dust-adminhttps://www.dustcollectorhq.com/wp-content/uploads/Aerodyne_logo-white-background.gifdust-admin2017-07-26 15:11:002025-10-31 16:14:49The Benefits of Using a VFD On a Dust Collection Exhaust Fan
Every dust collection system should have a manual damper near each hood/pickup point to balance the system. It can be used to shut off portions of the system.
https://www.dustcollectorhq.com/wp-content/uploads/AER-Blog-June17.jpg192192dust-adminhttps://www.dustcollectorhq.com/wp-content/uploads/Aerodyne_logo-white-background.gifdust-admin2017-06-28 17:19:002025-10-31 16:14:49How Important are Dampers in a Dust Collection System?
Dust collection systems consist of 4 major items can cause a dust collection sys. to underperform (exhaust fan, dust collector, ductwork,&hoods/pickup points)
https://www.dustcollectorhq.com/wp-content/uploads/PY-Arzyz-02.jpg600800dust-adminhttps://www.dustcollectorhq.com/wp-content/uploads/Aerodyne_logo-white-background.gifdust-admin2017-06-15 13:15:002026-08-04 11:06:31Dust Collection System: 4 Major Items That Can Cause Underperformance
The cyclone will allow you to recover the dust without contamination from the filters. The cyclone can be washed out or wiped down between colors. This saves in both maintenance time and spare parts costs.
https://www.dustcollectorhq.com/wp-content/uploads/IMG_1540.jpg12241632dust-adminhttps://www.dustcollectorhq.com/wp-content/uploads/Aerodyne_logo-white-background.gifdust-admin2017-05-25 17:50:002025-10-31 16:14:48Dust Collection Systems: Product Recovery and Cyclone Pre-filters
With the release of NFPA 652 and 654, manufacturers that create dust in their processes are required to conduct a Dust Hazard Analysis if the dust is explosive.
When you have a combustible dust, not only does your dust collector require to be protected against a deflagration, but the airlock must contain the event.
https://www.dustcollectorhq.com/wp-content/uploads/dr-dust-2.jpg288336dust-adminhttps://www.dustcollectorhq.com/wp-content/uploads/Aerodyne_logo-white-background.gifdust-admin2017-04-10 12:30:002026-07-30 09:10:27Dust Collection Systems: Rotary Valves and NFPA-69
By measuring the differential pressure across your dust collector, you are monitoring your system performance.A sudden change =suddenly increased or decreased.
The Benefits of Using a VFD On a Dust Collection Exhaust Fan
How Important are Dampers in a Dust Collection System?
Dust Collection System: 4 Major Items That Can Cause Underperformance
Aerodyne At Ceramics Expo 2017
Dust Collection Systems: Product Recovery and Cyclone Pre-filters
Dust Collection Systems: Dust Hazard Analysis (DHA) and NFPA 652
Dust Collection Systems: 5 Best Solutions of Dust Collection Airlocks
Dust Collection Systems: Rotary Valves and NFPA-69
Dust Collection Systems: Instrumentation 101 – Differential Pressure Gages
Dust Collection Systems: Fan Wheels 101