<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Pressure Gauge in Dust Collection System | Aerodyne Environmental</title>
	<atom:link href="https://www.dustcollectorhq.com/category/pressure-gauge-in-dust-collection-system/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.dustcollectorhq.com</link>
	<description>Industrial Dust Collector &#38; Airlock Valve Specialist</description>
	<lastBuildDate>Mon, 26 Oct 2026 19:05:43 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.dustcollectorhq.com/wp-content/uploads/Aerodyne-favicon-500-x-500-png-36x36.png</url>
	<title>Pressure Gauge in Dust Collection System | Aerodyne Environmental</title>
	<link>https://www.dustcollectorhq.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Pulse Cleaning Bags Too Often?</title>
		<link>https://www.dustcollectorhq.com/the-negatives-of-pulsing-bags-too-often/</link>
		
		<dc:creator><![CDATA[dust-admin]]></dc:creator>
		<pubDate>Tue, 28 Mar 2023 01:04:00 +0000</pubDate>
				<category><![CDATA[Cyclone Pre-Filter]]></category>
		<category><![CDATA[Pressure Gauge in Dust Collection System]]></category>
		<guid isPermaLink="false">https://www.dustcollectorhq.com/the-negatives-of-pulsing-bags-too-often/</guid>

					<description><![CDATA[<p>The Negatives of Pulsing Bags Too Often</p>
The post <a href="https://www.dustcollectorhq.com/the-negatives-of-pulsing-bags-too-often/">Pulse Cleaning Bags Too Often?</a> first appeared on <a href="https://www.dustcollectorhq.com">Aerodyne Environmental</a>.]]></description>
										<content:encoded><![CDATA[<p style="font-size: 18px;"><span style="font-family: Arial, Helvetica, sans-serif;">Using bags, cartridges, and filters for <em><strong><a href="https://www.dustcollectorhq.com/dust-collectors/" target="_blank" rel="noopener">dust collection</a> </strong></em>is one of the best ways of capturing dust particles in the airstream. The filter allows the air to pass by while preventing the particulate from passing through. The dust particles then begin to build up on the filter. This build up helps prevent smaller particles from passing through, but also makes it harder for air to pass through. Over time this dust layer will prevent the air from passing though, thereby plugging up the filters. <img decoding="async" style="width: 346px; float: right; margin: 10px 0px 10px 10px;" src="https://www.dustcollectorhq.com/wp-content/uploads/filter.jpg" alt="filter" width="346" /></span></p>
<p style="font-size: 18px;"><span style="font-family: Arial, Helvetica, sans-serif;">To prevent <em><strong><a href="/how-do-i-extend-the-life-of-my-filters" target="_blank" rel="noopener">plugging of the filters</a>,</strong></em> they are often cleaned by blowing air through them in the opposite direction of airflow. Baghouses and cartridge collectors use compressed air which expands the filter slightly so that it drops off material. The dust then falls into the hopper below. The periodic expansion of the filters will over time cause holes to form.</span></p>
<h2 style="font-size: 18px; font-weight: bold;"><span style="font-family: Arial, Helvetica, sans-serif; color: #000000;">Dangers in Cleaning Out Filters</span></h2>
<p style="font-size: 18px;"><span style="font-family: Arial, Helvetica, sans-serif;">For HEPA filters and other inline filters, it is not as easy to <em><strong><a href="/how-to-clean-various-dust-collectors" target="_blank" rel="noopener">clean filters during operation</a>.</strong> </em>Usually the filter needs to be pulled out of service and then air is blown through the filter (in the opposite way) to remove the dust from the filter. However, using high pressure air to blow out the filters can also cause holes to develop in the filter.</span></p>
<p style="font-size: 18px;"><span style="font-family: Arial, Helvetica, sans-serif;">When these holes develop in filters, air will rush through the holes, taking dust with them. Since the holes in the media have lower resistance than the filters, air will find it easier to go through the hole than the filters. This will cause the hole to grow in size over time. And as more and more air passes through the hole, more dust will bypass the filter and contaminate the cleaned air.</span></p>
<h2 style="font-size: 18px; font-weight: bold;"><span style="font-family: Arial, Helvetica, sans-serif; color: #000000;">Pressure Gage Is Recommended</span></h2>
<p style="font-size: 18px;"><span style="font-family: Arial, Helvetica, sans-serif;">When using filters, it is always recommended to install a <em><strong><a href="/dust-collection-systems-instrumentation-101-differential-pressure-gages" target="_blank" rel="noopener">differential pressure gage</a></strong></em> across the filter. As dust builds up on the filter, the differential pressure will increase. And as the pressure drop across the filter increases, less air will be flowing through the filter. So when you notice a high pressure drop across the filter, this means it is time to remove and replace or clean the filters. If you don’t replace the filter and the pressure drop decreases then it probably means that you have a hole (or holes) in your filter.</span></p>
<p style="font-size: 18px;"><span style="font-family: Arial, Helvetica, sans-serif;">So when you are cleaning your filters, be sure to check that no holes develop. The holes can be caused by high airflow when blowing out or after repeated expansions by compressed air. The use of differential pressure gages will help you identify if a hole develops before noticing dust in the clean air. If you find that you are cleaning or replacing filters too often, installing a <em><strong><a href="https://www.dustcollectorhq.com/latest-videos/five-signs-your-dust-collection-system-needs-a-pre-filter/" target="_blank" rel="noopener">pre-filter such as a cyclone</a></strong></em> can lower the dust loading on the filters, thereby extending their life.</span></p>
<hr />
<p style="font-size: 18px;"><span style="font-family: arial, helvetica, sans-serif;">To learn more about which dust collector, please contact our experts at 440-543-7400 or visit our website: <em><strong><a href="http://www.dustcollectorhq.com/">www.dustcollectorhq.com</a>.</strong></em></span></p>
<hr />
<hr />
<p style="font-size: 18px;"><span style="font-family: arial, helvetica, sans-serif;">To improve efficiency and safety, there is no substitute for an on-site inspection by an experienced expert. Click below to start with a free 20-minute phone consultation by clicking the button.</span></p>
<p style="font-size: 16px;"><a href="https://info.dustcollectorhq.com/dr.-dust-dust-collection-system-evaluation" target="_blank" rel="noopener"><img decoding="async" src="https://cdn2.hubspot.net/hubshot/19/07/30/750c4e66-3f64-45f4-ba76-c07d0b30d368.png" /></a></p>
<p style="font-size: 16px;"><span id="more-3110"></span></p>The post <a href="https://www.dustcollectorhq.com/the-negatives-of-pulsing-bags-too-often/">Pulse Cleaning Bags Too Often?</a> first appeared on <a href="https://www.dustcollectorhq.com">Aerodyne Environmental</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Accessories to Consider with Your Dust Collection System &#124; Aerodyne</title>
		<link>https://www.dustcollectorhq.com/accessories-to-consider-with-your-dust-collection-system/</link>
		
		<dc:creator><![CDATA[dust-admin]]></dc:creator>
		<pubDate>Mon, 25 Jul 2022 17:30:00 +0000</pubDate>
				<category><![CDATA[Dust Collection System]]></category>
		<category><![CDATA[Pressure Gauge in Dust Collection System]]></category>
		<guid isPermaLink="false">https://www.dustcollectorhq.com/accessories-to-consider-with-your-dust-collection-system/</guid>

					<description><![CDATA[<p>Accessories to Consider with Your Dust Collection System</p>
The post <a href="https://www.dustcollectorhq.com/accessories-to-consider-with-your-dust-collection-system/">Accessories to Consider with Your Dust Collection System | Aerodyne</a> first appeared on <a href="https://www.dustcollectorhq.com">Aerodyne Environmental</a>.]]></description>
										<content:encoded><![CDATA[<p style="font-size: 18px;"><span style="font-family: Arial, Helvetica, sans-serif;"><a href="https://www.dustcollectorhq.com/dust-collectors/about-dust-collection/" target="_blank" rel="noopener"><em><strong>Dust collectors</strong></em></a> have multiple accessories that can be used to help optimize the system. Some are used to protect the system, some are used to monitor the system, and some are used to make the system operate smoothly. The following blog is a quick description of a few of them.<img decoding="async" style="width: 263px; float: right; margin: 20px 0px 10px 10px;" src="https://www.dustcollectorhq.com/wp-content/uploads/VFDs_g-scaled.gif" alt="VFDs_g" width="263" /></span></p>
<h2 style="font-size: 18px; font-weight: bold;"><span style="font-family: Arial, Helvetica, sans-serif; color: #000000;">Meters</span></h2>
<ul style="font-size: 18px;">
<li><span style="font-family: Arial, Helvetica, sans-serif;">Airflow meters – allow you to measure the airflow through the system. Effective to know if your system is operating correctly.</span></li>
<li><span style="font-family: Arial, Helvetica, sans-serif;">Differential <em><strong><a href="/dust-collection-systems-instrumentation-101-differential-pressure-gages" target="_blank" rel="noopener">pressure gage</a> </strong></em>– used to monitor the pressure drop through the dust collector. Often can warn you if your dust collector is having an issue (sudden change in pressure drop) or when maintenance is required (high or low pressure drops).</span></li>
<li><span style="font-family: Arial, Helvetica, sans-serif;">Level meter – allows you to monitor the amount of material in your hopper. This will tell you if you’ve bridged the<em><strong> <a href="/the-hidden-dangers-of-overfilled-hoppers-in-dust-collection-system" target="_blank" rel="noopener">hopper</a>,</strong></em> your airlock stopped, etc.</span></li>
<li><span style="font-family: Arial, Helvetica, sans-serif;">Temperature gage – allows you to monitor the temperature of your system and prevent damage to components such as filters, seals, instrumentation, etc.</span></li>
</ul>
<h2 style="font-size: 18px; font-weight: bold;"><span style="font-family: Arial, Helvetica, sans-serif; color: #000000;">Valves and Tools</span></h2>
<ul style="font-size: 18px;">
<li><span style="font-family: Arial, Helvetica, sans-serif;"><a href="/how-vibrators-can-help-hopper-flow" target="_blank" rel="noopener"><em><strong>Vibrators</strong></em></a> – allow you to shake material in the hopper, preventing bridging.</span></li>
<li><span style="font-family: Arial, Helvetica, sans-serif;">Air nozzles – blow compressed air into the hopper preventing dust from settling and bridging</span></li>
<li><span style="font-family: Arial, Helvetica, sans-serif;"><a href="https://www.dustcollectorhq.com/airlock-valves/" target="_blank" rel="noopener"><em><strong>Airlocks</strong></em></a> – allows material to leave the dust collector hopper and prevent air from passing through (entering or leaving the system)</span></li>
<li><span style="font-family: Arial, Helvetica, sans-serif;">Zero speed switch – used to monitor the airlock to make sure it is operating and inform the operators when it stops.</span></li>
<li><span style="font-family: Arial, Helvetica, sans-serif;">VFD – perhaps the most useful of all this allows you to increase or decrease the <em><strong><a href="/how-important-is-the-airflow-in-a-dust-collection-system" target="_blank" rel="noopener">airflow in the system</a></strong></em> by adjusting the operating speed of the exhaust fan.</span></li>
</ul>
<h2 style="font-size: 18px; font-weight: bold;"><span style="font-family: Arial, Helvetica, sans-serif; color: #000000;">Explosive Applications</span></h2>
<ul style="font-size: 18px;">
<li><span style="font-family: Arial, Helvetica, sans-serif;"><a href="/installing-explosion-vents-indoor-vs-outdoor" target="_blank" rel="noopener"><em><strong>Explosion vent </strong></em></a>– mounted on the dust collector, it allows an explosive overpressure to relieve in a controlled fashion preventing destruction of the dust collector and surrounding areas.</span></li>
<li><span style="font-family: Arial, Helvetica, sans-serif;">Flameless explosion vent – similar to the above but designed to cool down the release so no flame is vented out. Can be used indoors.</span></li>
<li><span style="font-family: Arial, Helvetica, sans-serif;">Chemical suppression – used to inject an inert material into the dust collector which will <em><strong><a href="/industrial-dust-control-prevents-explosions-and-hazards/" target="_blank" rel="noopener">prevent the dust </a></strong></em>in the vessel from exploding.</span></li>
<li><span style="font-family: Arial, Helvetica, sans-serif;">Thermal sensor – monitors the heat in the dust collector and is used to activate chemical suppression.</span></li>
<li><span style="font-family: Arial, Helvetica, sans-serif;">Pressure sensor – monitors the pressure in the dust collector and is used to activate chemical suppression when over pressure is measured.</span></li>
<li><span style="font-family: Arial, Helvetica, sans-serif;">Isolation gate – installed before the dust collector, this prevents an <em><strong><a href="/is-your-dust-explosive" target="_blank" rel="noopener">explosion in the dust collector</a></strong></em> from moving back into the building and the rest of the process.</span></li>
</ul>
<hr />
<p style="font-size: 18px;"><span style="font-family: arial, helvetica, sans-serif;">For more dust collection and material handling literature, visit our website at<em><strong> <a href="http://www.dustcollectorhq.com/">www.dustcollectorhq.com</a>.</strong></em></span></p>
<p style="font-size: 18px;"><span style="font-family: arial, helvetica, sans-serif;">To improve efficiency and safety, there is no substitute for an on-site inspection by an experienced expert. <a href="https://b7aa.share.hsforms.com/2U5INo30uTMqAHiF11sL87w" target="_blank" rel="noopener">Click here</a> to discuss your application with a member of our engineering team. We&#8217;re here to help! </span></p>
<p style="font-size: 16px;">
<p style="font-size: 16px;">The post <a href="https://www.dustcollectorhq.com/accessories-to-consider-with-your-dust-collection-system/">Accessories to Consider with Your Dust Collection System | Aerodyne</a> first appeared on <a href="https://www.dustcollectorhq.com">Aerodyne Environmental</a>.]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
